Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu100A
Number of auxiliary contacts as normally closed contact0
Overload release current setting0 - 0A
Number of poles4
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Rated voltage415 - 415V
Degree of protection (IP)IP20
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release800 - 1200A
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-4-A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0 .. 0A

Number of poles

4

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Rated voltage

415 .. 415V

Degree of protection (IP)

IP20

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Integrated earth fault protection

Adjustment range undelayed short-circuit release

800 .. 1200A

With under voltage release

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.