Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Overload release current setting0 - 0A
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Type of control elementRocker lever
With under voltage releaseNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Integrated earth fault protectionNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release256 - 384A
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Rated permanent current Iu20A
Number of poles4
Rated voltage415 - 415V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-4-A20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Overload release current setting

0 .. 0A

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Type of control element

Rocker lever

With under voltage release

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Integrated earth fault protection

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

256 .. 384A

DIN rail (top hat rail) mounting optional

With switched-off indicator

Rated permanent current Iu

20A

Number of poles

4

Rated voltage

415 .. 415V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.