Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protectionNo
Rated voltage415 - 415V
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Overload release current setting0 - 0A
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Rated permanent current Iu125A
Adjustment range undelayed short-circuit release800 - 1200A
With switched-off indicatorNo
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-A125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Integrated earth fault protection

Rated voltage

415 .. 415V

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Overload release current setting

0 .. 0A

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Rated permanent current Iu

125A

Adjustment range undelayed short-circuit release

800 .. 1200A

With switched-off indicator

Motor drive optional

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

With under voltage release

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.