Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of poles3
Overload release current setting0 - 0A
Rated permanent current Iu40A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated voltage415 - 415V
Type of control elementRocker lever
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
Degree of protection (IP)IP20
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release320 - 480A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-A40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Overload release current setting

0 .. 0A

Rated permanent current Iu

40A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated voltage

415 .. 415V

Type of control element

Rocker lever

Motor drive integrated

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

Degree of protection (IP)

IP20

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

320 .. 480A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.