Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Motor drive integratedNo
Adjustment range undelayed short-circuit release800 - 1200A
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitScrew connection
Degree of protection (IP)IP20
Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release0 - 0A
Overload release current setting0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Rated voltage415 - 415V
Position of connection for main current circuitFront side
Rated permanent current Iu80A
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally closed contact0
Motor drive optionalNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-A80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Motor drive integrated

Adjustment range undelayed short-circuit release

800 .. 1200A

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Screw connection

Degree of protection (IP)

IP20

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

0 .. 0A

Overload release current setting

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Rated voltage

415 .. 415V

Position of connection for main current circuit

Front side

Rated permanent current Iu

80A

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.