Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height230mm
With control elementNo
Number of digital outputs0
Number of digital inputs4
Power consumption20W
Number of analogue inputs1
Depth169mm
Number of HW-interfaces RS-4851
With optical interfaceNo
Number of analogue outputs0
Supporting protocol for LONNo
Supporting protocol for CANYes
Supporting protocol for ASINo
Number of HW-interfaces RS-2320
Number of HW-interfaces serial TTY0
Supporting protocol for TCP/IPNo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for PROFIBUSNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Number of HW-interfaces industrial Ethernet0
Supporting protocol for DeviceNetNo
With PC connectionYes
Supporting protocol for other bus systemsYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Application in industrial area permittedYes
Mains voltage200 - 240V
Application in domestic- and commercial area permittedYes
Mains frequency50/60 Hz
Max. output at quadratic load at rated output voltage0.37kW
Type of converterU converter
Max. output at linear load at rated output voltage0.37kW
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Integrated breaking resistanceNo
Number of phases input1
Number of phases output3
Supporting protocol for PROFINET IONo
Max. output voltage250V
Supporting protocol for Foundation FieldbusNo
Max. output frequency300Hz
Supporting protocol for SafetyBUS pNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET CBANo
Supporting protocol for AS-Interface Safety at WorkNo
Relative symmetric net frequency tolerance10%
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Relative symmetric net voltage tolerance10%
Degree of protection (NEMA)Other
Nominal output current I2N2.3A
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE11-122D3NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

230mm

With control element

Number of digital outputs

0

Number of digital inputs

4

Power consumption

20W

Number of analogue inputs

1

Depth

169mm

Number of HW-interfaces RS-485

1

With optical interface

Number of analogue outputs

0

Supporting protocol for LON

Supporting protocol for CAN

Supporting protocol for ASI

Number of HW-interfaces RS-232

0

Number of HW-interfaces serial TTY

0

Supporting protocol for TCP/IP

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-422

0

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for PROFIBUS

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for DeviceNet

With PC connection

Supporting protocol for other bus systems

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS-Safety

Application in industrial area permitted

Mains voltage

200 .. 240V

Application in domestic- and commercial area permitted

Mains frequency

50/60 Hz

Max. output at quadratic load at rated output voltage

0.37kW

Type of converter

U converter

Max. output at linear load at rated output voltage

0.37kW

Number of interfaces PROFINET

0

4-quadrant operation possible

Integrated breaking resistance

Number of phases input

1

Number of phases output

3

Supporting protocol for PROFINET IO

Max. output voltage

250V

Supporting protocol for Foundation Fieldbus

Max. output frequency

300Hz

Supporting protocol for SafetyBUS p

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

Supporting protocol for AS-Interface Safety at Work

Relative symmetric net frequency tolerance

10%

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Relative symmetric net voltage tolerance

10%

Degree of protection (NEMA)

Other

Nominal output current I2N

2.3A

Supporting protocol for BACnet

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.