  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Power consumption17W
Height230mm
Depth169mm
Number of digital outputs0
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs0
Number of digital inputs4
Supporting protocol for LONNo
Number of analogue inputs1
With control elementNo
Number of HW-interfaces serial TTY0
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Supporting protocol for INTERBUSNo
Supporting protocol for Data-HighwayNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Number of HW-interfaces RS-2320
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Number of HW-interfaces RS-4851
Supporting protocol for DeviceNetNo
Supporting protocol for CANNo
Degree of protection (IP)IP20
With PC connectionYes
Supporting protocol for other bus systemsYes
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Number of interfaces PROFINET0
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output frequency300Hz
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Type of converterU converter
4-quadrant operation possibleNo
Mains voltage200 - 240V
Number of phases output3
Max. output at quadratic load at rated output voltage0.25kW
Integrated breaking resistanceNo
Mains frequency50/60 Hz
Supporting protocol for EtherNet/IPYes
Max. output at linear load at rated output voltage0.25kW
Supporting protocol for AS-Interface Safety at WorkNo
Number of phases input1
Supporting protocol for PROFINET CBANo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output voltage250V
Supporting protocol for BACnetNo
Nominal output current I2N1.4A
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-121D4NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Power consumption

17W

Height

230mm

Depth

169mm

Number of digital outputs

0

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

0

Number of digital inputs

4

Supporting protocol for LON

Number of analogue inputs

1

With control element

Number of HW-interfaces serial TTY

0

With optical interface

Number of HW-interfaces other

0

Supporting protocol for KNX

Supporting protocol for Modbus

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Supporting protocol for INTERBUS

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for ASI

Number of HW-interfaces RS-232

0

Supporting protocol for SUCONET

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Number of HW-interfaces RS-485

1

Supporting protocol for DeviceNet

Supporting protocol for CAN

Degree of protection (IP)

IP20

With PC connection

Supporting protocol for other bus systems

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Number of interfaces PROFINET

0

Application in industrial area permitted

Application in domestic- and commercial area permitted

Max. output frequency

300Hz

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Type of converter

U converter

4-quadrant operation possible

Mains voltage

200 .. 240V

Number of phases output

3

Max. output at quadratic load at rated output voltage

0.25kW

Integrated breaking resistance

Mains frequency

50/60 Hz

Supporting protocol for EtherNet/IP

Max. output at linear load at rated output voltage

0.25kW

Supporting protocol for AS-Interface Safety at Work

Number of phases input

1

Supporting protocol for PROFINET CBA

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output voltage

250V

Supporting protocol for BACnet

Nominal output current I2N

1.4A

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO