Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height230mm
Depth169mm
Number of digital outputs0
Power consumption20W
Number of HW-interfaces industrial Ethernet0
Number of analogue outputs0
Number of digital inputs4
With control elementNo
Number of HW-interfaces RS-2320
Number of analogue inputs1
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Number of HW-interfaces other0
Number of HW-interfaces RS-4851
Supporting protocol for CANNo
With optical interfaceNo
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Supporting protocol for PROFIBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Application in industrial area permittedYes
Number of phases output3
Mains voltage200 - 240V
Degree of protection (IP)IP20
With PC connectionYes
Mains frequency50/60 Hz
Type of converterU converter
4-quadrant operation possibleNo
Max. output frequency300Hz
Number of interfaces PROFINET0
Relative symmetric net voltage tolerance10%
Number of phases input1
Supporting protocol for INTERBUS-SafetyNo
Max. output at quadratic load at rated output voltage0.37kW
Application in domestic- and commercial area permittedYes
Supporting protocol for other bus systemsYes
Integrated breaking resistanceNo
Supporting protocol for SERCOSNo
Relative symmetric net frequency tolerance10%
Max. output at linear load at rated output voltage0.37kW
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Nominal output current I2N2.3A
Supporting protocol for SafetyBUS pNo
Max. output voltage250V
Supporting protocol for PROFIsafeNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-122D3NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

230mm

Depth

169mm

Number of digital outputs

0

Power consumption

20W

Number of HW-interfaces industrial Ethernet

0

Number of analogue outputs

0

Number of digital inputs

4

With control element

Number of HW-interfaces RS-232

0

Number of analogue inputs

1

Supporting protocol for LON

Number of HW-interfaces serial TTY

0

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Number of HW-interfaces other

0

Number of HW-interfaces RS-485

1

Supporting protocol for CAN

With optical interface

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Supporting protocol for PROFIBUS

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Application in industrial area permitted

Number of phases output

3

Mains voltage

200 .. 240V

Degree of protection (IP)

IP20

With PC connection

Mains frequency

50/60 Hz

Type of converter

U converter

4-quadrant operation possible

Max. output frequency

300Hz

Number of interfaces PROFINET

0

Relative symmetric net voltage tolerance

10%

Number of phases input

1

Supporting protocol for INTERBUS-Safety

Max. output at quadratic load at rated output voltage

0.37kW

Application in domestic- and commercial area permitted

Supporting protocol for other bus systems

Integrated breaking resistance

Supporting protocol for SERCOS

Relative symmetric net frequency tolerance

10%

Max. output at linear load at rated output voltage

0.37kW

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Nominal output current I2N

2.3A

Supporting protocol for SafetyBUS p

Max. output voltage

250V

Supporting protocol for PROFIsafe

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.