Technical specifications

Height230mm
Power consumption59W
Width45mm
Depth169mm
Number of HW-interfaces RS-4220
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Supporting protocol for Data-HighwayNo
Supporting protocol for ModbusYes
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of digital outputs0
Supporting protocol for KNXNo
Number of analogue outputs0
Number of HW-interfaces other0
Number of digital inputs4
Number of HW-interfaces RS-4851
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for LONNo
Supporting protocol for CANNo
With control elementNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-2320
Number of analogue inputs1
With optical interfaceNo
Supporting protocol for SUCONETNo
With PC connectionYes
Max. output at linear load at rated output voltage1.5kW
Number of interfaces PROFINET0
Mains frequency50/60 Hz
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
4-quadrant operation possibleNo
Supporting protocol for INTERBUS-SafetyNo
Max. output frequency300Hz
Application in domestic- and commercial area permittedYes
Degree of protection (IP)IP20
Supporting protocol for other bus systemsYes
Relative symmetric net voltage tolerance10%
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Number of phases input1
Number of phases output3
Relative symmetric net frequency tolerance10%
Mains voltage200 - 240V
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Integrated breaking resistanceNo
Supporting protocol for PROFINET CBANo
Max. output at quadratic load at rated output voltage1.5kW
Application in industrial area permittedYes
Supporting protocol for PROFIsafeNo
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Nominal output current I2N7A
Degree of protection (NEMA)Other
Max. output voltage250V
Supporting protocol for PROFINET IONo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-127D0NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

230mm

Power consumption

59W

Width

45mm

Depth

169mm

Number of HW-interfaces RS-422

0

Supporting protocol for DeviceNet

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces parallel

0

Number of digital outputs

0

Supporting protocol for KNX

Number of analogue outputs

0

Number of HW-interfaces other

0

Number of digital inputs

4

Number of HW-interfaces RS-485

1

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for LON

Supporting protocol for CAN

With control element

Supporting protocol for TCP/IP

Number of HW-interfaces RS-232

0

Number of analogue inputs

1

With optical interface

Supporting protocol for SUCONET

With PC connection

Max. output at linear load at rated output voltage

1.5kW

Number of interfaces PROFINET

0

Mains frequency

50/60 Hz

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

4-quadrant operation possible

Supporting protocol for INTERBUS-Safety

Max. output frequency

300Hz

Application in domestic- and commercial area permitted

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Relative symmetric net voltage tolerance

10%

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Number of phases input

1

Number of phases output

3

Relative symmetric net frequency tolerance

10%

Mains voltage

200 .. 240V

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Integrated breaking resistance

Supporting protocol for PROFINET CBA

Max. output at quadratic load at rated output voltage

1.5kW

Application in industrial area permitted

Supporting protocol for PROFIsafe

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Nominal output current I2N

7A

Degree of protection (NEMA)

Other

Max. output voltage

250V

Supporting protocol for PROFINET IO

Related products