Technical specifications

Height230mm
With control elementNo
Number of analogue inputs1
Power consumption105W
Number of digital inputs4
Number of digital outputs0
Depth169mm
Number of analogue outputs0
Width90mm
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4851
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Supporting protocol for INTERBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusYes
With PC connectionYes
Number of HW-interfaces other0
Supporting protocol for CANNo
4-quadrant operation possibleNo
Supporting protocol for ASINo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Number of HW-interfaces parallel0
With optical interfaceNo
Supporting protocol for other bus systemsYes
Degree of protection (IP)IP20
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for TCP/IPNo
Supporting protocol for SERCOSNo
Mains voltage200 - 240V
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Type of converterU converter
Number of phases output3
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedYes
Degree of protection (NEMA)Other
Number of phases input1
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for BACnetNo
Max. output frequency300Hz
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Relative symmetric net frequency tolerance10%
Nominal output current I2N9.6A
Integrated breaking resistanceNo
Supporting protocol for Foundation FieldbusNo
Application in industrial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage250V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-129D6FN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

230mm

With control element

Number of analogue inputs

1

Power consumption

105W

Number of digital inputs

4

Number of digital outputs

0

Depth

169mm

Number of analogue outputs

0

Width

90mm

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Supporting protocol for INTERBUS

Supporting protocol for SUCONET

Supporting protocol for Modbus

With PC connection

Number of HW-interfaces other

0

Supporting protocol for CAN

4-quadrant operation possible

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of HW-interfaces parallel

0

With optical interface

Supporting protocol for other bus systems

Degree of protection (IP)

IP20

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Supporting protocol for TCP/IP

Supporting protocol for SERCOS

Mains voltage

200 .. 240V

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Type of converter

U converter

Number of phases output

3

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Degree of protection (NEMA)

Other

Number of phases input

1

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for BACnet

Max. output frequency

300Hz

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Relative symmetric net frequency tolerance

10%

Nominal output current I2N

9.6A

Integrated breaking resistance

Supporting protocol for Foundation Fieldbus

Application in industrial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

250V