Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementNo
Number of digital inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces RS-2320
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Width90mm
Number of HW-interfaces other0
Number of analogue outputs0
Power consumption105W
Number of analogue inputs1
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4220
Number of HW-interfaces USB0
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
With optical interfaceNo
Number of digital outputs0
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Number of HW-interfaces RS-4851
Supporting protocol for PROFIBUSNo
Depth169mm
Height230mm
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for Data-HighwayNo
Max. output frequency300Hz
4-quadrant operation possibleNo
With PC connectionYes
Type of converterU converter
Number of interfaces PROFINET0
Number of phases input1
Mains frequency50/60 Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNetNo
Integrated breaking resistanceNo
Supporting protocol for SUCONETNo
Number of phases output3
Mains voltage200 - 240V
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for ModbusYes
Relative symmetric net frequency tolerance10%
Application in industrial area permittedYes
Degree of protection (IP)IP20
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for other bus systemsYes
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET IONo
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Supporting protocol for BACnetNo
Supporting protocol for DeviceNet SafetyNo
Max. output voltage250V
Nominal output current I2N9.6A
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-129D6NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Number of digital inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-232

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Width

90mm

Number of HW-interfaces other

0

Number of analogue outputs

0

Power consumption

105W

Number of analogue inputs

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces USB

0

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

With optical interface

Number of digital outputs

0

Supporting protocol for KNX

Supporting protocol for TCP/IP

Number of HW-interfaces RS-485

1

Supporting protocol for PROFIBUS

Depth

169mm

Height

230mm

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for Data-Highway

Max. output frequency

300Hz

4-quadrant operation possible

With PC connection

Type of converter

U converter

Number of interfaces PROFINET

0

Number of phases input

1

Mains frequency

50/60 Hz

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet

Integrated breaking resistance

Supporting protocol for SUCONET

Number of phases output

3

Mains voltage

200 .. 240V

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for Modbus

Relative symmetric net frequency tolerance

10%

Application in industrial area permitted

Degree of protection (IP)

IP20

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for other bus systems

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET IO

Supporting protocol for EtherNet/IP

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Supporting protocol for BACnet

Supporting protocol for DeviceNet Safety

Max. output voltage

250V

Nominal output current I2N

9.6A

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.