Details
- Low-voltage switchgear and control gear (automation)
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 - 480V
Number of phases output
3
Max. output at quadratic load at rated output voltage
5.5kW
Max. output at linear load at rated output voltage
5.5kW
Max. output frequency
300Hz
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Number of analogue outputs
0
Nominal output current I2N
11.3A
Max. output voltage
500V
Power consumption
159W
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of analogue inputs
1
Supporting protocol for CAN
Yes
Supporting protocol for PROFIBUS
No
Number of digital inputs
4
Supporting protocol for TCP/IP
No
With control element
No
Number of HW-interfaces other
0
Application in domestic- and commercial area permitted
Yes
Number of digital outputs
0
With optical interface
No
Application in industrial area permitted
Yes
With PC connection
Yes
Integrated breaking resistance
No
Degree of protection (IP)
IP20
4-quadrant operation possible
No
Degree of protection (NEMA)
Other
Type of converter
U converter
Height
230mm
Width
90mm
Depth
169mm
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Related products
DE11-34011NN-N20N

Details
- Low-voltage switchgear and control gear (automation)
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 .. 480V
Number of phases output
3
Max. output at quadratic load at rated output voltage
5.5kW
Max. output at linear load at rated output voltage
5.5kW
Max. output frequency
300Hz
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Number of analogue outputs
0
Nominal output current I2N
11.3A
Max. output voltage
500V
Power consumption
159W
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of analogue inputs
1
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Number of digital inputs
4
Supporting protocol for TCP/IP
With control element
Number of HW-interfaces other
0
Application in domestic- and commercial area permitted
Number of digital outputs
0
With optical interface
Application in industrial area permitted
With PC connection
Integrated breaking resistance
Degree of protection (IP)
IP20
4-quadrant operation possible
Degree of protection (NEMA)
Other
Type of converter
U converter
Height
230mm
Width
90mm
Depth
169mm
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0