Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width45mm
Height230mm
Power consumption28W
Depth169mm
Number of analogue outputs0
Supporting protocol for LONNo
Number of analogue inputs1
Number of digital outputs0
With control elementNo
Number of digital inputs4
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces RS-4851
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-2320
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for SUCONETNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Degree of protection (IP)IP20
With PC connectionYes
Supporting protocol for other bus systemsYes
Mains voltage380 - 480V
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces USB0
Number of interfaces PROFINET0
Number of phases input3
Integrated breaking resistanceNo
4-quadrant operation possibleNo
Application in industrial area permittedYes
Type of converterU converter
Number of phases output3
Max. output frequency300Hz
Application in domestic- and commercial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Max. output at linear load at rated output voltage0.75kW
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Relative symmetric net voltage tolerance10%
Relative symmetric net frequency tolerance10%
Max. output at quadratic load at rated output voltage0.75kW
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Nominal output current I2N2.1A
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Mains frequency50/60 Hz
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE11-342D1NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

230mm

Power consumption

28W

Depth

169mm

Number of analogue outputs

0

Supporting protocol for LON

Number of analogue inputs

1

Number of digital outputs

0

With control element

Number of digital inputs

4

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-232

0

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Number of HW-interfaces other

0

With optical interface

Supporting protocol for SUCONET

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Degree of protection (IP)

IP20

With PC connection

Supporting protocol for other bus systems

Mains voltage

380 .. 480V

Supporting protocol for SERCOS

Supporting protocol for INTERBUS-Safety

Supporting protocol for INTERBUS

Number of HW-interfaces USB

0

Number of interfaces PROFINET

0

Number of phases input

3

Integrated breaking resistance

4-quadrant operation possible

Application in industrial area permitted

Type of converter

U converter

Number of phases output

3

Max. output frequency

300Hz

Application in domestic- and commercial area permitted

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Max. output at linear load at rated output voltage

0.75kW

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Relative symmetric net voltage tolerance

10%

Relative symmetric net frequency tolerance

10%

Max. output at quadratic load at rated output voltage

0.75kW

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Max. output voltage

500V

Nominal output current I2N

2.1A

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Mains frequency

50/60 Hz

Degree of protection (NEMA)

Other