Technical specifications

Width45mm
Height230mm
Depth169mm
Power consumption47W
Number of digital inputs4
Number of analogue inputs1
With control elementNo
Number of digital outputs0
Number of HW-interfaces RS-4851
Number of analogue outputs0
Number of HW-interfaces parallel0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces serial TTY0
Supporting protocol for DeviceNetNo
Supporting protocol for ASINo
Supporting protocol for CANYes
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces other0
Supporting protocol for Data-HighwayNo
Supporting protocol for KNXNo
Number of HW-interfaces USB0
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for other bus systemsYes
With PC connectionYes
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Supporting protocol for INTERBUS-SafetyNo
Application in industrial area permittedYes
Supporting protocol for PROFINET IONo
Number of interfaces PROFINET0
Relative symmetric net frequency tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for PROFINET CBANo
Supporting protocol for EtherNet/IPYes
Max. output frequency300Hz
Max. output at quadratic load at rated output voltage1.5kW
Application in domestic- and commercial area permittedYes
Number of phases output3
Mains voltage380 - 480V
Relative symmetric net voltage tolerance10%
Integrated breaking resistanceNo
Type of converterU converter
Max. output at linear load at rated output voltage1.5kW
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Number of phases input3
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output voltage500V
Supporting protocol for BACnetNo
Degree of protection (NEMA)Other
Nominal output current I2N3.6A

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE11-343D6FN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

45mm

Height

230mm

Depth

169mm

Power consumption

47W

Number of digital inputs

4

Number of analogue inputs

1

With control element

Number of digital outputs

0

Number of HW-interfaces RS-485

1

Number of analogue outputs

0

Number of HW-interfaces parallel

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces serial TTY

0

Supporting protocol for DeviceNet

Supporting protocol for ASI

Supporting protocol for CAN

Supporting protocol for PROFIBUS

With optical interface

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces other

0

Supporting protocol for Data-Highway

Supporting protocol for KNX

Number of HW-interfaces USB

0

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

With PC connection

4-quadrant operation possible

Mains frequency

50/60 Hz

Supporting protocol for INTERBUS-Safety

Application in industrial area permitted

Supporting protocol for PROFINET IO

Number of interfaces PROFINET

0

Relative symmetric net frequency tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Max. output frequency

300Hz

Max. output at quadratic load at rated output voltage

1.5kW

Application in domestic- and commercial area permitted

Number of phases output

3

Mains voltage

380 .. 480V

Relative symmetric net voltage tolerance

10%

Integrated breaking resistance

Type of converter

U converter

Max. output at linear load at rated output voltage

1.5kW

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Number of phases input

3

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Max. output voltage

500V

Supporting protocol for BACnet

Degree of protection (NEMA)

Other

Nominal output current I2N

3.6A

Related products