Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width90mm
Supporting protocol for LONNo
Power consumption240W
Number of digital outputs0
With control elementNo
Number of analogue inputs1
Height230mm
Number of digital inputs4
Depth169mm
Number of analogue outputs0
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4851
Number of HW-interfaces RS-2320
Number of HW-interfaces parallel0
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces industrial Ethernet0
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces other0
With optical interfaceNo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Supporting protocol for CANNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusYes
With PC connectionYes
Degree of protection (IP)IP20
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUS-SafetyNo
Mains frequency50/60 Hz
Number of phases input3
Mains voltage380 - 480V
Number of interfaces PROFINET0
Integrated breaking resistanceNo
4-quadrant operation possibleNo
Type of converterU converter
Number of phases output3
Application in industrial area permittedYes
Supporting protocol for DeviceNet SafetyNo
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage7.5kW
Supporting protocol for AS-Interface Safety at WorkNo
Max. output frequency300Hz
Max. output at linear load at rated output voltage7.5kW
Application in domestic- and commercial area permittedYes
Supporting protocol for EtherNet/IPYes
Max. output voltage500V
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for BACnetNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N16A
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-34016NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

90mm

Supporting protocol for LON

Power consumption

240W

Number of digital outputs

0

With control element

Number of analogue inputs

1

Height

230mm

Number of digital inputs

4

Depth

169mm

Number of analogue outputs

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces RS-232

0

Number of HW-interfaces parallel

0

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for ASI

Supporting protocol for PROFIBUS

Number of HW-interfaces other

0

With optical interface

Supporting protocol for KNX

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for Modbus

With PC connection

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS-Safety

Mains frequency

50/60 Hz

Number of phases input

3

Mains voltage

380 .. 480V

Number of interfaces PROFINET

0

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Number of phases output

3

Application in industrial area permitted

Supporting protocol for DeviceNet Safety

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

7.5kW

Supporting protocol for AS-Interface Safety at Work

Max. output frequency

300Hz

Max. output at linear load at rated output voltage

7.5kW

Application in domestic- and commercial area permitted

Supporting protocol for EtherNet/IP

Max. output voltage

500V

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

16A

Degree of protection (NEMA)

Other

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.