Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control elementNo
Depth169mm
Power consumption56W
Height230mm
Width90mm
Number of digital outputs0
Number of digital inputs4
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces USB0
Number of HW-interfaces RS-4851
Supporting protocol for ASINo
Number of HW-interfaces serial TTY0
Number of analogue inputs1
Number of HW-interfaces other0
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for ModbusYes
Supporting protocol for CANNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
Supporting protocol for SUCONETNo
Number of HW-interfaces RS-4220
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Supporting protocol for DeviceNetNo
With optical interfaceNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-2320
Number of analogue outputs0
With PC connectionYes
Mains frequency50/60 Hz
Number of phases output3
4-quadrant operation possibleNo
Supporting protocol for AS-Interface Safety at WorkNo
Integrated breaking resistanceNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for PROFINET IONo
Max. output at linear load at rated output voltage2.2kW
Mains voltage380 - 480V
Degree of protection (IP)IP20
Application in industrial area permittedYes
Supporting protocol for PROFINET CBANo
Number of phases input3
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Relative symmetric net voltage tolerance10%
Supporting protocol for Foundation FieldbusNo
Supporting protocol for INTERBUS-SafetyNo
Max. output frequency300Hz
Number of interfaces PROFINET0
Type of converterU converter
Supporting protocol for EtherNet/IPYes
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for SERCOSNo
Max. output voltage500V
Supporting protocol for SafetyBUS pNo
Nominal output current I2N5A
Supporting protocol for BACnetNo
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-345D0FN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

With control element

Depth

169mm

Power consumption

56W

Height

230mm

Width

90mm

Number of digital outputs

0

Number of digital inputs

4

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Supporting protocol for ASI

Number of HW-interfaces serial TTY

0

Number of analogue inputs

1

Number of HW-interfaces other

0

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for Modbus

Supporting protocol for CAN

Supporting protocol for KNX

Supporting protocol for TCP/IP

Supporting protocol for SUCONET

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Supporting protocol for DeviceNet

With optical interface

Supporting protocol for INTERBUS

Number of HW-interfaces RS-232

0

Number of analogue outputs

0

With PC connection

Mains frequency

50/60 Hz

Number of phases output

3

4-quadrant operation possible

Supporting protocol for AS-Interface Safety at Work

Integrated breaking resistance

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFINET IO

Max. output at linear load at rated output voltage

2.2kW

Mains voltage

380 .. 480V

Degree of protection (IP)

IP20

Application in industrial area permitted

Supporting protocol for PROFINET CBA

Number of phases input

3

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Relative symmetric net voltage tolerance

10%

Supporting protocol for Foundation Fieldbus

Supporting protocol for INTERBUS-Safety

Max. output frequency

300Hz

Number of interfaces PROFINET

0

Type of converter

U converter

Supporting protocol for EtherNet/IP

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for SERCOS

Max. output voltage

500V

Supporting protocol for SafetyBUS p

Nominal output current I2N

5A

Supporting protocol for BACnet

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Related products