Technical specifications

Height230mm
Depth169mm
Width90mm
Power consumption90W
With control elementNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4220
Number of digital inputs4
Number of HW-interfaces RS-2320
Number of analogue outputs0
Number of HW-interfaces USB0
Number of analogue inputs1
Number of HW-interfaces parallel0
Number of HW-interfaces RS-4851
Number of digital outputs0
Supporting protocol for LONNo
Supporting protocol for KNXNo
Supporting protocol for TCP/IPNo
With optical interfaceNo
Supporting protocol for ModbusYes
Supporting protocol for INTERBUSNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for CANNo
Number of HW-interfaces other0
Supporting protocol for SUCONETNo
Supporting protocol for DeviceNetNo
Supporting protocol for Data-HighwayNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Number of phases output3
Supporting protocol for INTERBUS-SafetyNo
Integrated breaking resistanceNo
Type of converterU converter
Number of interfaces PROFINET0
Application in industrial area permittedYes
Degree of protection (IP)IP20
Number of phases input3
Mains voltage380 - 480V
Mains frequency50/60 Hz
4-quadrant operation possibleNo
With PC connectionYes
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Max. output frequency300Hz
Relative symmetric net voltage tolerance10%
Max. output at quadratic load at rated output voltage3kW
Supporting protocol for PROFINET CBANo
Relative symmetric net frequency tolerance10%
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage3kW
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for Foundation FieldbusNo
Nominal output current I2N6.6A
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)Other
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Max. output voltage500V
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-346D6FN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Height

230mm

Depth

169mm

Width

90mm

Power consumption

90W

With control element

Number of HW-interfaces serial TTY

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-422

0

Number of digital inputs

4

Number of HW-interfaces RS-232

0

Number of analogue outputs

0

Number of HW-interfaces USB

0

Number of analogue inputs

1

Number of HW-interfaces parallel

0

Number of HW-interfaces RS-485

1

Number of digital outputs

0

Supporting protocol for LON

Supporting protocol for KNX

Supporting protocol for TCP/IP

With optical interface

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for CAN

Number of HW-interfaces other

0

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for other bus systems

Supporting protocol for SERCOS

Number of phases output

3

Supporting protocol for INTERBUS-Safety

Integrated breaking resistance

Type of converter

U converter

Number of interfaces PROFINET

0

Application in industrial area permitted

Degree of protection (IP)

IP20

Number of phases input

3

Mains voltage

380 .. 480V

Mains frequency

50/60 Hz

4-quadrant operation possible

With PC connection

Supporting protocol for DeviceNet Safety

Supporting protocol for EtherNet/IP

Max. output frequency

300Hz

Relative symmetric net voltage tolerance

10%

Max. output at quadratic load at rated output voltage

3kW

Supporting protocol for PROFINET CBA

Relative symmetric net frequency tolerance

10%

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

3kW

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for Foundation Fieldbus

Nominal output current I2N

6.6A

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

Other

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Max. output voltage

500V