Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width90mm
Supporting protocol for LONNo
Number of digital outputs0
Number of HW-interfaces industrial Ethernet0
Height230mm
Power consumption90W
With control elementNo
Number of digital inputs4
Number of analogue outputs0
Number of HW-interfaces RS-4220
Number of analogue inputs1
Number of HW-interfaces RS-2320
Depth169mm
Number of HW-interfaces RS-4851
With optical interfaceNo
Number of HW-interfaces other0
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Number of HW-interfaces parallel0
Supporting protocol for TCP/IPNo
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Supporting protocol for ModbusYes
Supporting protocol for KNXNo
Supporting protocol for CANNo
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
4-quadrant operation possibleNo
Mains voltage380 - 480V
Number of interfaces PROFINET0
Degree of protection (IP)IP20
Supporting protocol for other bus systemsYes
Supporting protocol for DeviceNetNo
Supporting protocol for INTERBUSNo
Mains frequency50/60 Hz
Supporting protocol for SUCONETNo
Supporting protocol for Data-HighwayNo
Supporting protocol for SERCOSNo
Number of phases output3
Supporting protocol for Foundation FieldbusNo
Application in domestic- and commercial area permittedYes
Max. output at quadratic load at rated output voltage3kW
Supporting protocol for PROFINET CBANo
Max. output frequency300Hz
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPYes
Type of converterU converter
Integrated breaking resistanceNo
Max. output at linear load at rated output voltage3kW
Number of phases input3
Application in industrial area permittedYes
Relative symmetric net frequency tolerance10%
Relative symmetric net voltage tolerance10%
Supporting protocol for PROFIsafeNo
Degree of protection (NEMA)Other
Supporting protocol for SafetyBUS pNo
Nominal output current I2N6.6A
Supporting protocol for BACnetNo
Supporting protocol for PROFINET IONo
Max. output voltage500V

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-346D6NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Width

90mm

Supporting protocol for LON

Number of digital outputs

0

Number of HW-interfaces industrial Ethernet

0

Height

230mm

Power consumption

90W

With control element

Number of digital inputs

4

Number of analogue outputs

0

Number of HW-interfaces RS-422

0

Number of analogue inputs

1

Number of HW-interfaces RS-232

0

Depth

169mm

Number of HW-interfaces RS-485

1

With optical interface

Number of HW-interfaces other

0

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Number of HW-interfaces parallel

0

Supporting protocol for TCP/IP

Number of HW-interfaces serial TTY

0

Number of HW-interfaces USB

0

Supporting protocol for Modbus

Supporting protocol for KNX

Supporting protocol for CAN

With PC connection

Supporting protocol for INTERBUS-Safety

4-quadrant operation possible

Mains voltage

380 .. 480V

Number of interfaces PROFINET

0

Degree of protection (IP)

IP20

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for INTERBUS

Mains frequency

50/60 Hz

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for SERCOS

Number of phases output

3

Supporting protocol for Foundation Fieldbus

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

3kW

Supporting protocol for PROFINET CBA

Max. output frequency

300Hz

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Type of converter

U converter

Integrated breaking resistance

Max. output at linear load at rated output voltage

3kW

Number of phases input

3

Application in industrial area permitted

Relative symmetric net frequency tolerance

10%

Relative symmetric net voltage tolerance

10%

Supporting protocol for PROFIsafe

Degree of protection (NEMA)

Other

Supporting protocol for SafetyBUS p

Nominal output current I2N

6.6A

Supporting protocol for BACnet

Supporting protocol for PROFINET IO

Max. output voltage

500V

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.