Technical specifications

Number of digital inputs4
Number of digital outputs0
Depth169mm
Height230mm
With control elementNo
Number of analogue outputs0
Number of analogue inputs1
Power consumption120W
Width90mm
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
Number of HW-interfaces USB0
Supporting protocol for Data-HighwayNo
Number of HW-interfaces other0
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4851
Degree of protection (IP)IP20
Supporting protocol for CANNo
Number of HW-interfaces serial TTY0
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for DeviceNetNo
Supporting protocol for TCP/IPNo
Supporting protocol for other bus systemsYes
Supporting protocol for SUCONETNo
With optical interfaceNo
Supporting protocol for ASINo
With PC connectionYes
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380 - 480V
Supporting protocol for SERCOSNo
Number of interfaces PROFINET0
4-quadrant operation possibleNo
Mains frequency50/60 Hz
Number of phases input3
Relative symmetric net voltage tolerance10%
Application in domestic- and commercial area permittedYes
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Max. output at linear load at rated output voltage4kW
Supporting protocol for PROFIsafeNo
Integrated breaking resistanceNo
Type of converterU converter
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Max. output voltage500V
Application in industrial area permittedYes
Max. output at quadratic load at rated output voltage4kW
Supporting protocol for PROFINET CBANo
Number of phases output3
Relative symmetric net frequency tolerance10%
Max. output frequency300Hz
Supporting protocol for EtherNet/IPYes
Supporting protocol for PROFINET IONo
Nominal output current I2N8.5A
Degree of protection (NEMA)Other
Supporting protocol for BACnetNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DE1-348D5NN-N20N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Number of digital inputs

4

Number of digital outputs

0

Depth

169mm

Height

230mm

With control element

Number of analogue outputs

0

Number of analogue inputs

1

Power consumption

120W

Width

90mm

Number of HW-interfaces RS-232

0

Number of HW-interfaces RS-422

0

Supporting protocol for LON

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces parallel

0

Supporting protocol for PROFIBUS

Number of HW-interfaces USB

0

Supporting protocol for Data-Highway

Number of HW-interfaces other

0

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

1

Degree of protection (IP)

IP20

Supporting protocol for CAN

Number of HW-interfaces serial TTY

0

Supporting protocol for KNX

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for TCP/IP

Supporting protocol for other bus systems

Supporting protocol for SUCONET

With optical interface

Supporting protocol for ASI

With PC connection

Supporting protocol for INTERBUS-Safety

Mains voltage

380 .. 480V

Supporting protocol for SERCOS

Number of interfaces PROFINET

0

4-quadrant operation possible

Mains frequency

50/60 Hz

Number of phases input

3

Relative symmetric net voltage tolerance

10%

Application in domestic- and commercial area permitted

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Max. output at linear load at rated output voltage

4kW

Supporting protocol for PROFIsafe

Integrated breaking resistance

Type of converter

U converter

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Max. output voltage

500V

Application in industrial area permitted

Max. output at quadratic load at rated output voltage

4kW

Supporting protocol for PROFINET CBA

Number of phases output

3

Relative symmetric net frequency tolerance

10%

Max. output frequency

300Hz

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Nominal output current I2N

8.5A

Degree of protection (NEMA)

Other

Supporting protocol for BACnet