Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as emergency stop installation
No
Version as safety switch
No
Number of switches
1
Version as reversing switch
No
Rated permanent current Iu
160A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
160A
Rated operating voltage
690 - 690V
Rated permanent current at AC-23, 400 V
140A
Conditioned rated short-circuit current Iq
50kA
Switching power at 400 V
0kW
Rated operation power at AC-23, 400 V
80kW
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Motor drive optional
No
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Device construction
Complete device in housing
Suitable for floor mounting
Yes
Motor drive integrated
No
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
No
Colour control element
Other
Type of control element
Short thumb-grip
Suitable for intermediate mounting
No
Rated short-time withstand current lcw
2.5kA
Interlockable
Yes
Rated operation power at AC-3, 400 V
0kW
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
No
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Height
200mm
Width
200mm
Depth
280mm
DMM-160/3N/I5/C-B

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as emergency stop installation
Version as safety switch
Number of switches
1
Version as reversing switch
Rated permanent current Iu
160A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
160A
Rated operating voltage
690 .. 690V
Rated permanent current at AC-23, 400 V
140A
Conditioned rated short-circuit current Iq
50kA
Switching power at 400 V
0kW
Rated operation power at AC-23, 400 V
80kW
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Device construction
Complete device in housing
Suitable for floor mounting
Motor drive integrated
Suitable for front mounting centre
Suitable for front mounting 4-hole
Suitable for distribution board installation
Colour control element
Other
Type of control element
Short thumb-grip
Suitable for intermediate mounting
Rated short-time withstand current lcw
2.5kA
Interlockable
Rated operation power at AC-3, 400 V
0kW
Type of electrical connection of main circuit
Screw connection
With pre-assembled cabling
Degree of protection (IP), front side
IP65
Degree of protection (NEMA)
12
Height
200mm
Width
200mm
Depth
280mm