Aleta.hr

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Height200mm
Width200mm
Rated permanent current Iu160A
Depth280mm
Number of auxiliary contacts as normally open contact0
Rated operation power at AC-3, 400 V0kW
Number of auxiliary contacts as normally closed contact0
Number of poles4
Version as emergency stop installationNo
Conditioned rated short-circuit current Iq50kA
InterlockableYes
Version as safety switchNo
Version as main switchYes
Type of control elementShort thumb-grip
Rated operating voltage690 - 690V
Version as maintenance-/service switchYes
Number of switches1
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as change-over contact0
Degree of protection (IP), front sideIP65
Motor drive integratedNo
Colour control elementOther
Rated short-time withstand current lcw2.5kA
Rated operation power at AC-23, 400 V80kW
Suitable for intermediate mountingNo
Voltage release optionalNo
Suitable for distribution board installationNo
Rated permanent current at AC-21, 400 V160A
Degree of protection (NEMA)12
Suitable for front mounting 4-holeNo
Suitable for front mounting centreNo
Rated permanent current at AC-23, 400 V140A
Motor drive optionalNo
Version as reversing switchNo
Suitable for floor mountingYes
Max. rated operation voltage Ue AC690V
Device constructionComplete device in housing
Switching power at 400 V0kW
With pre-assembled cablingNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

DMM-160/3N/I5/C-B

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Switch disconnector (low voltage)
  • 1 KOM
  • EATON

Technical specifications

Height

200mm

Width

200mm

Rated permanent current Iu

160A

Depth

280mm

Number of auxiliary contacts as normally open contact

0

Rated operation power at AC-3, 400 V

0kW

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Version as emergency stop installation

Conditioned rated short-circuit current Iq

50kA

Interlockable

Version as safety switch

Version as main switch

Type of control element

Short thumb-grip

Rated operating voltage

690 .. 690V

Version as maintenance-/service switch

Number of switches

1

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP), front side

IP65

Motor drive integrated

Colour control element

Other

Rated short-time withstand current lcw

2.5kA

Rated operation power at AC-23, 400 V

80kW

Suitable for intermediate mounting

Voltage release optional

Suitable for distribution board installation

Rated permanent current at AC-21, 400 V

160A

Degree of protection (NEMA)

12

Suitable for front mounting 4-hole

Suitable for front mounting centre

Rated permanent current at AC-23, 400 V

140A

Motor drive optional

Version as reversing switch

Suitable for floor mounting

Max. rated operation voltage Ue AC

690V

Device construction

Complete device in housing

Switching power at 400 V

0kW

With pre-assembled cabling

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.