Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU1E-SWD-2DD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Depth
85.6mm
Supporting protocol for LON
Number of HW-interfaces serial TTY
0
Width
56.9mm
Number of digital outputs
2
Number of HW-interfaces RS-232
0
Time delay at signal exchange
0 .. 0.2ms
Number of HW-interfaces industrial Ethernet
0
Number of digital inputs
2
Height
20.1mm
Suitable for safety functions
Voltage type of supply voltage
DC
Number of HW-interfaces RS-485
0
Input current at signal 1
4mA
Number of HW-interfaces USB
0
Number of HW-interfaces RS-422
0
Supporting protocol for ASI
Supporting protocol for TCP/IP
Type of voltage (input voltage)
DC
Number of HW-interfaces other
0
Number of HW-interfaces parallel
0
Supporting protocol for PROFIBUS
With optical interface
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for KNX
Supporting protocol for Modbus
Output current
0.5A
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Explosion safety category for gas
None
Explosion safety category for dust
None
Supporting protocol for INTERBUS
System accessory
Number of HW-interfaces Wireless
0
Front built-in possible
Type of digital output
Other
Short-circuit protection, outputs available
Rail mounting possible
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for SERCOS
Fieldbus connection over separate bus coupler possible
Degree of protection (IP)
IP69K
Number of interfaces PROFINET
0
Type of electric connection
Screw connection
Performance level according to EN ISO 13849-1
None
Supply voltage DC
0 .. 28.8V
Rack-assembly possible
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for Foundation Fieldbus
Permitted voltage at output
20.4 .. 28.8V
Supporting protocol for PROFINET CBA
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage AC 50 Hz
0 .. 0V
Radio standard Wi-Fi 802.11
IO link master
Supporting protocol for PROFINET IO
Wall mounting/direct mounting
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Radio standard Bluetooth
Radio standard GPRS
Radio standard GSM
Type of output voltage
DC
Permitted voltage at input
20.4 .. 28.8V
Digital outputs configurable
Digital inputs configurable
Radio standard UMTS
SIL according to IEC 61508
None
Certified for UL hazardous location division 2
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location division 1
Supporting protocol for EtherCAT
Certified for UL hazardous location class I
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group A (acetylene)