Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Depth85.6mm
Supporting protocol for LONNo
Number of HW-interfaces serial TTY0
Width56.9mm
Number of HW-interfaces RS-2320
Time delay at signal exchange0 - 0.2ms
Number of HW-interfaces industrial Ethernet0
Height20.1mm
Suitable for safety functionsNo
Number of HW-interfaces RS-4850
Input current at signal 14mA
Number of HW-interfaces USB0
Number of HW-interfaces RS-4220
Supporting protocol for ASINo
Supporting protocol for TCP/IPNo
Type of voltage (input voltage)DC
Number of HW-interfaces other0
Number of HW-interfaces parallel0
Supporting protocol for PROFIBUSNo
With optical interfaceNo
Supporting protocol for SUCONETNo
Supporting protocol for CANNo
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Output current0.5A
Appendant operation agent (Ex ib)No
Appendant operation agent (Ex ia)No
Explosion safety category for gasNone
Explosion safety category for dustNone
Supporting protocol for INTERBUSNo
System accessoryYes
Number of HW-interfaces Wireless0
Front built-in possibleNo
Type of digital outputOther
Short-circuit protection, outputs availableYes
Rail mounting possibleYes
Supporting protocol for Data-HighwayNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for other bus systemsYes
Supporting protocol for SERCOSNo
Fieldbus connection over separate bus coupler possibleYes
Number of interfaces PROFINET0
Type of electric connectionScrew connection
Performance level according to EN ISO 13849-1None
Supply voltage DC0 - 28.8V
Rack-assembly possibleNo
Supporting protocol for PROFIsafeNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Permitted voltage at output20.4 - 28.8V
Supporting protocol for PROFINET CBANo
Supply voltage AC 60 Hz0 - 0V
Supply voltage AC 50 Hz0 - 0V
Radio standard Wi-Fi 802.11No
IO link masterNo
Supporting protocol for PROFINET IONo
Wall mounting/direct mountingYes
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Radio standard BluetoothNo
Radio standard GPRSNo
Radio standard GSMNo
Type of output voltageDC
Permitted voltage at input20.4 - 28.8V
Digital outputs configurableYes
Digital inputs configurableYes
Radio standard UMTSNo
SIL according to IEC 61508None
Certified for UL hazardous location division 2No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location division 1No
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location group F (carbonaceous dusts)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group G (non-conductive dusts)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location group A (acetylene)No
Number of digital inputs2
Number of digital outputs2
Voltage type of supply voltageDC
Degree of protection (IP)IP69K