Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU1E-SWD-2DX

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Number of digital outputs
0
Number of HW-interfaces industrial Ethernet
0
Width
56.9mm
Voltage type of supply voltage
DC
Suitable for safety functions
Number of digital inputs
2
Number of HW-interfaces RS-422
0
Input current at signal 1
4mA
Number of HW-interfaces serial TTY
0
Depth
85.6mm
Number of HW-interfaces parallel
0
Time delay at signal exchange
0 .. 0.2ms
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces USB
0
Supporting protocol for LON
Height
20.1mm
Supporting protocol for PROFIBUS
Supporting protocol for ASI
With optical interface
Number of HW-interfaces other
0
Supporting protocol for INTERBUS
Type of voltage (input voltage)
DC
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for KNX
Output current
0A
Supporting protocol for other bus systems
Short-circuit protection, outputs available
Appendant operation agent (Ex ia)
Supporting protocol for DeviceNet
Fieldbus connection over separate bus coupler possible
Supporting protocol for Data-Highway
Type of digital output
None
Explosion safety category for dust
None
Rail mounting possible
Supporting protocol for SUCONET
System accessory
Type of electric connection
Screw connection
Explosion safety category for gas
None
Degree of protection (IP)
IP69K
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Appendant operation agent (Ex ib)
Number of HW-interfaces Wireless
0
Number of interfaces PROFINET
0
Supporting protocol for DeviceNet Safety
Performance level according to EN ISO 13849-1
None
Supporting protocol for EtherNet/IP
IO link master
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Radio standard Bluetooth
Permitted voltage at output
20.4 .. 28.8V
Permitted voltage at input
20.4 .. 28.8V
Supporting protocol for Foundation Fieldbus
Type of output voltage
DC
Supply voltage DC
0 .. 28.8V
Radio standard Wi-Fi 802.11
Supply voltage AC 50 Hz
0 .. 0V
Supply voltage AC 60 Hz
0 .. 0V
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for EtherCAT
Radio standard GPRS
Radio standard UMTS
SIL according to IEC 61508
None
Digital outputs configurable
Radio standard GSM
Digital inputs configurable
Certified for UL hazardous location division 2
Certified for UL hazardous location class II
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location class I
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group D (propane)