Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU2E-SWD-4DD

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Width
56.9mm
Height
20.1mm
Depth
98mm
Suitable for safety functions
Time delay at signal exchange
0 .. 0.2ms
Number of HW-interfaces industrial Ethernet
0
Number of digital inputs
4
Input current at signal 1
4mA
Number of HW-interfaces RS-422
0
Supporting protocol for LON
Number of HW-interfaces serial TTY
0
Number of digital outputs
4
Number of HW-interfaces parallel
0
Supporting protocol for ASI
Number of HW-interfaces RS-485
0
Voltage type of supply voltage
DC
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Supporting protocol for TCP/IP
With optical interface
Type of voltage (input voltage)
DC
Supporting protocol for KNX
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Type of digital output
Other
Rail mounting possible
Output current
0.5A
Explosion safety category for dust
None
Short-circuit protection, outputs available
System accessory
Number of interfaces PROFINET
0
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Degree of protection (IP)
IP69K
Appendant operation agent (Ex ia)
Type of electric connection
Screw connection
Number of HW-interfaces Wireless
0
Supporting protocol for other bus systems
Supporting protocol for SERCOS
Fieldbus connection over separate bus coupler possible
Front built-in possible
Supporting protocol for INTERBUS-Safety
Wall mounting/direct mounting
Rack-assembly possible
Radio standard Bluetooth
Performance level according to EN ISO 13849-1
None
IO link master
Supporting protocol for Foundation Fieldbus
Supply voltage AC 60 Hz
0 .. 0V
Type of output voltage
DC
Supply voltage DC
0 .. 28.8V
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Radio standard Wi-Fi 802.11
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET CBA
Digital outputs configurable
Radio standard GSM
Supporting protocol for SafetyBUS p
Radio standard UMTS
Digital inputs configurable
Supply voltage AC 50 Hz
0 .. 0V
Permitted voltage at output
20.4 .. 28.8V
Supporting protocol for PROFINET IO
Permitted voltage at input
20.4 .. 28.8V
Supporting protocol for AS-Interface Safety at Work
Radio standard GPRS
Certified for UL hazardous location class I
SIL according to IEC 61508
None
Supporting protocol for EtherCAT
Certified for UL hazardous location division 1
Certified for UL hazardous location class III
Certified for UL hazardous location division 2
Certified for UL hazardous location class II
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group C (ethylene)