Details
- •Programmable logic controllers PLC
- •Fieldbus, decentr. periphery - digital I/O module
- •1 KOM
- •EATON
Technical specifications
Related products
EU2E-SWD-4DX

Why Register?
- View wholesale prices with discounts
- Real-time stock availability
- Access invoices and dispatch notes
- Order history and frequently ordered items
- Exclusive B2B offers
and much more...
Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Number of digital inputs
4
Depth
98mm
Height
20.1mm
Input current at signal 1
4mA
Width
56.9mm
Suitable for safety functions
Number of digital outputs
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Voltage type of supply voltage
DC
Time delay at signal exchange
0 .. 0.2ms
Supporting protocol for LON
Number of HW-interfaces industrial Ethernet
0
With optical interface
Supporting protocol for PROFIBUS
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces other
0
Supporting protocol for Data-Highway
Type of digital output
None
Type of voltage (input voltage)
DC
Supporting protocol for CAN
Supporting protocol for other bus systems
Output current
0A
Number of HW-interfaces parallel
0
Supporting protocol for KNX
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Rail mounting possible
Supporting protocol for ASI
Type of electric connection
Screw connection
Supporting protocol for SUCONET
Short-circuit protection, outputs available
Supporting protocol for INTERBUS
Explosion safety category for dust
None
Explosion safety category for gas
None
System accessory
Supporting protocol for PROFINET IO
Fieldbus connection over separate bus coupler possible
Number of HW-interfaces Wireless
0
Degree of protection (IP)
IP69K
Radio standard Wi-Fi 802.11
Front built-in possible
Supporting protocol for DeviceNet Safety
Rack-assembly possible
Radio standard Bluetooth
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
IO link master
Supporting protocol for SERCOS
Number of interfaces PROFINET
0
Supporting protocol for PROFINET CBA
Performance level according to EN ISO 13849-1
None
Supporting protocol for AS-Interface Safety at Work
Appendant operation agent (Ex ia)
Wall mounting/direct mounting
Supporting protocol for PROFIsafe
Appendant operation agent (Ex ib)
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for SafetyBUS p
Supply voltage DC
0 .. 28.8V
Permitted voltage at output
20.4 .. 28.8V
Supply voltage AC 60 Hz
0 .. 0V
Permitted voltage at input
20.4 .. 28.8V
Digital outputs configurable
Radio standard GPRS
Digital inputs configurable
Type of output voltage
DC
Radio standard UMTS
Certified for UL hazardous location class I
SIL according to IEC 61508
None
Certified for UL hazardous location class II
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Radio standard GSM
Supporting protocol for EtherCAT
Certified for UL hazardous location class III
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)