Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Current limiting class3
Rated voltage230V
Over voltage category3
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Release characteristicB
Rated current1.6A
Built-in depth70.5mm
Power loss2.8W
Width in number of modular spacings2
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
Ambient temperature during operating-25 - 75°C
Number of protected poles1
Explosion-proofNo
Flush-mounted installationNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B1,6/1N

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Current limiting class

3

Rated voltage

230V

Over voltage category

3

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Release characteristic

B

Rated current

1.6A

Built-in depth

70.5mm

Power loss

2.8W

Width in number of modular spacings

2

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Ambient temperature during operating

-25 .. 75°C

Number of protected poles

1

Explosion-proof

Flush-mounted installation

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.