Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui440V
Rated voltage415V
Built-in depth70.5mm
Rated current10A
Voltage typeAC
Frequency50 - 60Hz
Release characteristicB
Current limiting class3
Number of protected poles2
Explosion-proofNo
Power loss3.6W
Over voltage category3
Pollution degree2
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Additional equipment possibleYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B10/2-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated insulation voltage Ui

440V

Rated voltage

415V

Built-in depth

70.5mm

Rated current

10A

Voltage type

AC

Frequency

50 .. 60Hz

Release characteristic

B

Current limiting class

3

Number of protected poles

2

Explosion-proof

Power loss

3.6W

Over voltage category

3

Pollution degree

2

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

2

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Additional equipment possible

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.