Rated current16A
Built-in depth70.5mm
Voltage typeAC
Release characteristicB
Rated voltage415V
Frequency50 - 60Hz
Width in number of modular spacings3
Rated insulation voltage Ui440V
Pollution degree2
Current limiting class3
Number of protected poles3
Degree of protection (IP)IP20
Over voltage category3
Concurrently switching neutral conductorNo
Power loss6.9W
Explosion-proofNo
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B16/3-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

16A

Built-in depth

70.5mm

Voltage type

AC

Release characteristic

B

Rated voltage

415V

Frequency

50 .. 60Hz

Width in number of modular spacings

3

Rated insulation voltage Ui

440V

Pollution degree

2

Current limiting class

3

Number of protected poles

3

Degree of protection (IP)

IP20

Over voltage category

3

Concurrently switching neutral conductor

Power loss

6.9W

Explosion-proof

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible