Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Voltage typeAC
Rated voltage230V
Over voltage category3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Explosion-proofNo
Flush-mounted installationNo
Current limiting class3
Ambient temperature during operating-25 - 75°C
Rated insulation voltage Ui440V
Connectable conductor cross section multi-wired1 - 25mm²
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Width in number of modular spacings1
Power loss1.4W
Rated current2A
Release characteristicB
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B2/1

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 12 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Voltage type

AC

Rated voltage

230V

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Explosion-proof

Flush-mounted installation

Current limiting class

3

Ambient temperature during operating

-25 .. 75°C

Rated insulation voltage Ui

440V

Connectable conductor cross section multi-wired

1 .. 25mm²

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Width in number of modular spacings

1

Power loss

1.4W

Rated current

2A

Release characteristic

B

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.