Technical specifications

Number of poles (total)2
Release characteristicB
Built-in depth70.5mm
Rated current20A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of protected poles2
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated voltage415V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss6.6W
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Over voltage category3
Pollution degree2
Additional equipment possibleYes
Width in number of modular spacings2
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B20/2-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Release characteristic

B

Built-in depth

70.5mm

Rated current

20A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of protected poles

2

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated voltage

415V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

6.6W

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Over voltage category

3

Pollution degree

2

Additional equipment possible

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor