Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Current limiting class3
Voltage typeAC
Release characteristicB
Rated current3A
Number of protected poles2
Power loss4.4W
Rated voltage400V
Pollution degree2
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Over voltage category3
Width in number of modular spacings2
Frequency50 - 60Hz
Explosion-proofNo
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B3/2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Current limiting class

3

Voltage type

AC

Release characteristic

B

Rated current

3A

Number of protected poles

2

Power loss

4.4W

Rated voltage

400V

Pollution degree

2

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Over voltage category

3

Width in number of modular spacings

2

Frequency

50 .. 60Hz

Explosion-proof

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

2

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.