  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Built-in depth70.5mm
Number of protected poles1
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated current32A
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated voltage240V
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Power loss3.5W
Frequency50 - 60Hz
Current limiting class3
Over voltage category3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Pollution degree2
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Width in number of modular spacings1
Ambient temperature during operating-25 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B32/1-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Built-in depth

70.5mm

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated current

32A

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated voltage

240V

Flush-mounted installation

Concurrently switching neutral conductor

Power loss

3.5W

Frequency

50 .. 60Hz

Current limiting class

3

Over voltage category

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 75°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.