Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
Number of protected poles2
Rated insulation voltage Ui440V
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Built-in depth70.5mm
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated current4A
Ambient temperature during operating-25 - 75°C
Frequency50 - 60Hz
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Width in number of modular spacings2
Rated voltage400V
Explosion-proofNo
Release characteristicB
Over voltage category3
Connectable conductor cross section solid-core1 - 25mm²
Power loss3W
Connectable conductor cross section multi-wired1 - 25mm²

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B4/2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Rated insulation voltage Ui

440V

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Built-in depth

70.5mm

Concurrently switching neutral conductor

Flush-mounted installation

Rated current

4A

Ambient temperature during operating

-25 .. 75°C

Frequency

50 .. 60Hz

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Degree of protection (IP)

IP20

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Width in number of modular spacings

2

Rated voltage

400V

Explosion-proof

Release characteristic

B

Over voltage category

3

Connectable conductor cross section solid-core

1 .. 25mm²

Power loss

3W

Connectable conductor cross section multi-wired

1 .. 25mm²

Related products