Built-in depth70.5mm
Release characteristicB
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated voltage415V
Rated current4A
Rated insulation voltage Ui440V
Power loss4.2W
Rated impulse withstand voltage Uimp4kV
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Over voltage category3
Width in number of modular spacings3
Voltage typeAC
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B4/3-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Release characteristic

B

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated voltage

415V

Rated current

4A

Rated insulation voltage Ui

440V

Power loss

4.2W

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Over voltage category

3

Width in number of modular spacings

3

Voltage type

AC

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Degree of protection (IP)

IP20