Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)2
Built-in depth70.5mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Voltage typeDC
Current limiting class3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated current40A
Over voltage category3
Rated insulation voltage Ui440V
Additional equipment possibleYes
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated voltage500V
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Power loss8.1W
Pollution degree2
Number of protected poles2
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B40/2-DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

2

Built-in depth

70.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Voltage type

DC

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated current

40A

Over voltage category

3

Rated insulation voltage Ui

440V

Additional equipment possible

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated voltage

500V

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Power loss

8.1W

Pollution degree

2

Number of protected poles

2

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.