Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated current40A
Number of poles (total)3
Number of protected poles3
Frequency50 - 60Hz
Built-in depth70.5mm
Pollution degree2
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Degree of protection (IP)IP20
Rated voltage415V
Rated insulation voltage Ui440V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Concurrently switching neutral conductorNo
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Power loss10.2W
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Over voltage category3
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B40/3-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated current

40A

Number of poles (total)

3

Number of protected poles

3

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Pollution degree

2

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Degree of protection (IP)

IP20

Rated voltage

415V

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Power loss

10.2W

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Over voltage category

3

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.