Technical specifications

Number of poles (total)4
Built-in depth70.5mm
Number of protected poles4
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated current5A
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated voltage400V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Power loss6W
Current limiting class3
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Pollution degree2
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Width in number of modular spacings4
Over voltage category3
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B5/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

4

Built-in depth

70.5mm

Number of protected poles

4

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated current

5A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated voltage

400V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

6W

Current limiting class

3

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Pollution degree

2

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Width in number of modular spacings

4

Over voltage category

3

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20