Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Rated voltage415V
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated current6A
Built-in depth70.5mm
Power loss5.4W
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Current limiting class3
Concurrently switching neutral conductorNo
Over voltage category3
Flush-mounted installationNo
Voltage typeAC
Pollution degree2
Degree of protection (IP)IP20
Width in number of modular spacings3
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Explosion-proofNo
Connectable conductor cross section solid-core1 - 25mm²
Ambient temperature during operating-25 - 75°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B6/3-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Rated voltage

415V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated current

6A

Built-in depth

70.5mm

Power loss

5.4W

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

3

Flush-mounted installation

Voltage type

AC

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

3

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.