Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Number of poles (total)2
Release characteristicB
Number of protected poles2
Rated current7A
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Power loss4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated insulation voltage Ui440V
Current limiting class3
Width in number of modular spacings2
Connectable conductor cross section multi-wired1 - 25mm²
Explosion-proofNo
Rated voltage415V
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Over voltage category3
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B7/2-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of poles (total)

2

Release characteristic

B

Number of protected poles

2

Rated current

7A

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Power loss

4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Concurrently switching neutral conductor

Additional equipment possible

Rated insulation voltage Ui

440V

Current limiting class

3

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Explosion-proof

Rated voltage

415V

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Over voltage category

3

Pollution degree

2