Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated current8A
Release characteristicB
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated voltage240V
Number of protected poles1
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Power loss2.1W
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Flush-mounted installationNo
Degree of protection (IP)IP20
Pollution degree2
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Additional equipment possibleYes
Width in number of modular spacings1
Ambient temperature during operating-25 - 75°C
Frequency50 - 60Hz
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B8/1-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated current

8A

Release characteristic

B

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated voltage

240V

Number of protected poles

1

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

2.1W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Flush-mounted installation

Degree of protection (IP)

IP20

Pollution degree

2

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Additional equipment possible

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 75°C

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof