Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Rated current8A
Rated voltage400V
Release characteristicB
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Voltage typeAC
Number of poles (total)3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Current limiting class3
Rated insulation voltage Ui440V
Over voltage category3
Flush-mounted installationNo
Power loss6.4W
Frequency50 - 60Hz
Additional equipment possibleYes
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings3
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
Ambient temperature during operating-25 - 75°C
Explosion-proofNo

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-B8/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Rated current

8A

Rated voltage

400V

Release characteristic

B

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Voltage type

AC

Number of poles (total)

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Current limiting class

3

Rated insulation voltage Ui

440V

Over voltage category

3

Flush-mounted installation

Power loss

6.4W

Frequency

50 .. 60Hz

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.