Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Number of protected poles1
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core1 - 25mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated current0.16A
Width in number of modular spacings1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Rated voltage230V
Additional equipment possibleYes
Flush-mounted installationNo
Explosion-proofNo
Current limiting class3
Power loss1.5W
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp4kV
Over voltage category3
Release characteristicC

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C0,16/1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated current

0.16A

Width in number of modular spacings

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Rated voltage

230V

Additional equipment possible

Flush-mounted installation

Explosion-proof

Current limiting class

3

Power loss

1.5W

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Release characteristic

C