Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated current0.75A
Rated voltage400V
Built-in depth70.5mm
Over voltage category3
Release characteristicC
Rated insulation voltage Ui440V
Explosion-proofNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Connectable conductor cross section multi-wired1 - 25mm²
Power loss8.4W
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Ambient temperature during operating-25 - 75°C
Pollution degree2
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core1 - 25mm²
Width in number of modular spacings3
Number of protected poles3
Rated impulse withstand voltage Uimp4kV

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C0,75/3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

0.75A

Rated voltage

400V

Built-in depth

70.5mm

Over voltage category

3

Release characteristic

C

Rated insulation voltage Ui

440V

Explosion-proof

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Power loss

8.4W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Ambient temperature during operating

-25 .. 75°C

Pollution degree

2

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

3

Number of protected poles

3

Rated impulse withstand voltage Uimp

4kV

Related products

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.