Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Number of protected poles1
Number of poles (total)1
Release characteristicC
Rated current12A
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Voltage typeAC
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Pollution degree2
Degree of protection (IP)IP20
Power loss2.1W
Width in number of modular spacings1
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Explosion-proofNo
Current limiting class3
Over voltage category3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C12/1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of protected poles

1

Number of poles (total)

1

Release characteristic

C

Rated current

12A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Pollution degree

2

Degree of protection (IP)

IP20

Power loss

2.1W

Width in number of modular spacings

1

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Explosion-proof

Current limiting class

3

Over voltage category

3

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.