Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Built-in depth70.5mm
Rated current12A
Voltage typeAC
Rated insulation voltage Ui440V
Release characteristicC
Rated voltage400V
Current limiting class3
Over voltage category3
Power loss6.8W
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core1 - 25mm²
Explosion-proofNo
Pollution degree2
Number of protected poles4
Width in number of modular spacings4
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C12/4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Rated current

12A

Voltage type

AC

Rated insulation voltage Ui

440V

Release characteristic

C

Rated voltage

400V

Current limiting class

3

Over voltage category

3

Power loss

6.8W

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 25mm²

Explosion-proof

Pollution degree

2

Number of protected poles

4

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.