Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Degree of protection (IP)IP20
Number of protected poles3
Rated insulation voltage Ui440V
Over voltage category3
Rated current15A
Rated voltage415V
Pollution degree2
Current limiting class3
Voltage typeAC
Power loss6W
Release characteristicC
Concurrently switching neutral conductorNo
Width in number of modular spacings3
Explosion-proofNo
Built-in depth70.5mm
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of poles (total)3
Connectable conductor cross section solid-core1 - 25mm²
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C15/3-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Number of protected poles

3

Rated insulation voltage Ui

440V

Over voltage category

3

Rated current

15A

Rated voltage

415V

Pollution degree

2

Current limiting class

3

Voltage type

AC

Power loss

6W

Release characteristic

C

Concurrently switching neutral conductor

Width in number of modular spacings

3

Explosion-proof

Built-in depth

70.5mm

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of poles (total)

3

Connectable conductor cross section solid-core

1 .. 25mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Ambient temperature during operating

-25 .. 75°C