Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Number of poles (total)1
Release characteristicC
Rated current16A
Rated insulation voltage Ui440V
Rated voltage240V
Voltage typeAC
Rated impulse withstand voltage Uimp4kV
Number of protected poles1
Current limiting class3
Power loss2.3W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Over voltage category3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Connectable conductor cross section solid-core1 - 25mm²
Degree of protection (IP)IP20
Width in number of modular spacings1
Ambient temperature during operating-25 - 75°C
Explosion-proofNo
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C16/1-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Number of poles (total)

1

Release characteristic

C

Rated current

16A

Rated insulation voltage Ui

440V

Rated voltage

240V

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

1

Current limiting class

3

Power loss

2.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Over voltage category

3

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

2