Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current16A
Release characteristicC
Rated voltage415V
Rated insulation voltage Ui440V
Built-in depth70.5mm
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Current limiting class3
Frequency50 - 60Hz
Flush-mounted installationNo
Over voltage category3
Number of poles (total)2
Ambient temperature during operating-25 - 75°C
Degree of protection (IP)IP20
Pollution degree2
Width in number of modular spacings2
Number of protected poles2
Power loss4.6W
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Explosion-proofNo
Concurrently switching neutral conductorNo
Voltage typeAC
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section solid-core1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C16/2-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

16A

Release characteristic

C

Rated voltage

415V

Rated insulation voltage Ui

440V

Built-in depth

70.5mm

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Over voltage category

3

Number of poles (total)

2

Ambient temperature during operating

-25 .. 75°C

Degree of protection (IP)

IP20

Pollution degree

2

Width in number of modular spacings

2

Number of protected poles

2

Power loss

4.6W

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Explosion-proof

Concurrently switching neutral conductor

Voltage type

AC

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section solid-core

1 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.