Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Pollution degree2
Built-in depth70.5mm
Frequency50 - 60Hz
Rated voltage250V
Width in number of modular spacings2
Current limiting class3
Rated insulation voltage Ui440V
Voltage typeDC
Explosion-proofNo
Release characteristicC
Power loss2.8W
Over voltage category3
Rated current2A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Number of protected poles2
Connectable conductor cross section solid-core1 - 25mm²
Flush-mounted installationNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 75°C
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Concurrently switching neutral conductorNo
Number of poles (total)2

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C2/2-NA-DC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Pollution degree

2

Built-in depth

70.5mm

Frequency

50 .. 60Hz

Rated voltage

250V

Width in number of modular spacings

2

Current limiting class

3

Rated insulation voltage Ui

440V

Voltage type

DC

Explosion-proof

Release characteristic

C

Power loss

2.8W

Over voltage category

3

Rated current

2A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Number of protected poles

2

Connectable conductor cross section solid-core

1 .. 25mm²

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Concurrently switching neutral conductor

Number of poles (total)