Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth70.5mm
Voltage typeAC
Release characteristicC
Rated voltage240V
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Current limiting class3
Number of protected poles1
Connectable conductor cross section solid-core1 - 25mm²
Pollution degree2
Explosion-proofNo
Degree of protection (IP)IP20
Power loss2.8W
Width in number of modular spacings1
Over voltage category3
Rated current25A
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 75°C
Connectable conductor cross section multi-wired1 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C25/1-NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

70.5mm

Voltage type

AC

Release characteristic

C

Rated voltage

240V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Current limiting class

3

Number of protected poles

1

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

Explosion-proof

Degree of protection (IP)

IP20

Power loss

2.8W

Width in number of modular spacings

1

Over voltage category

3

Rated current

25A

Concurrently switching neutral conductor

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 75°C

Connectable conductor cross section multi-wired

1 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.