Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Rated current25A
Rated voltage415V
Frequency50 - 60Hz
Built-in depth70.5mm
Release characteristicC
Current limiting class3
Explosion-proofNo
Number of protected poles2
Width in number of modular spacings2
Concurrently switching neutral conductorNo
Rated insulation voltage Ui440V
Pollution degree2
Over voltage category3
Degree of protection (IP)IP20
Power loss5.6W
Ambient temperature during operating-25 - 75°C
Number of poles (total)2
Connectable conductor cross section solid-core1 - 25mm²
Additional equipment possibleYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

FAZ-C25/2-RT

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Rated current

25A

Rated voltage

415V

Frequency

50 .. 60Hz

Built-in depth

70.5mm

Release characteristic

C

Current limiting class

3

Explosion-proof

Number of protected poles

2

Width in number of modular spacings

2

Concurrently switching neutral conductor

Rated insulation voltage Ui

440V

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Power loss

5.6W

Ambient temperature during operating

-25 .. 75°C

Number of poles (total)

2

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.